Exploring the Benefits of drilling, Casing, and tubing in wellbore construction understanding the different types of casing and tubing used in Wellbore Construction Tensile and hardness requirements grade Yield strength MPa Tensile Strength Hardness a,c specified Wall thickness Allowable Hardness Variation b Type total Elongation Under Load min MPa max …
Exploring the Benefits of drilling, Casing, and tubing in wellbore construction
understanding the different types of casing and tubing used in Wellbore Construction
Tensile and hardness requirements | |||||||||
grade | Yield strength MPa | Tensile Strength | Hardness a,c | specified Wall thickness | Allowable Hardness Variation b | ||||
Type | total Elongation Under Load | min MPa | max | ||||||
min | max | HRC | HBW | mm | HRC | ||||
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
H40 | — | 0.5 | 276 | 552 | 414 | — | — | — | — |
J55 | — | 0.5 | 379 | 552 | 517 | — | — | — | — |
k55 | — | 0.5 | 379 | 552 | 655 | — | — | — | — |
n80 | 1 | 0.5 | 552 | 758 | 689 | — | — | — | — |
N80 | Q | 0.5 | 552 | 758 | 689 | — | — | — | — |
R95 | — | 0.5 | 655 | 758 | 724 | — | — | — | — |
l80 L80 | 1 | 0.5 | 552 | 655 | 655 | 23 | 241 | — | — |
L80 | 9Cr 13Cr | 0.5 | 552 | 655 | 655 | 23 | 241 | — | — |
0.5 | 552 | 655 | 655 | 23 | 241 | — | — | ||
C90 | 1 | 0.5 | 621 | 724 | 689 | 25.4 | 255 | £12.70 | 3 |
12.71 to 19.04 | 4 | ||||||||
19.05 to 25.39 | 5 | ||||||||
³ 25.40 | 6 | ||||||||
T95 | 1 | 0.5 | 655 | 758 | 724 | 25.4 | 255 | £12.70 | 3 |
12.71 to 19.04 | 4 | ||||||||
19.05 to 25.39 | 5 | ||||||||
³ 25.40 | 6 | ||||||||
C110 | — | 0.7 | 758 | 828 | 793 | 30 | 286 | £12.70 | 3 |
12.71 to 19.04 | 4 | ||||||||
19.05 to 25.39 | 5 | ||||||||
³ 25.40 | 6 | ||||||||
p110 | — | 0.6 | 758 | 965 | 862 | — | — | — | — |
Q125 | 1 | 0.65 | 862 | 1034 | 931 | b | — | £12.70 | 3 |
12.71 to 19.04 19.05 | 4 | ||||||||
5 | |||||||||
a In case of dispute, laboratory Rockwell C hardness testing shall be used as the referee method. | |||||||||
b No hardness limits are specified, but the maximum variation is restricted as a manufacturing control in accordance with 7.8 and 7.9. | |||||||||
c for through-wall hardness tests of grades L80 (all types), c90, T95 and C110, the requirements stated in HRC scale are for maximum mean hardness number. |